Skip to content
Response time varies by location and service availability.
Error Code

U-Line Ice Maker Er16 Code: Water Drain Error

Error code Er16
Appliance Ice Maker
Quick answer

Er16 reports a drain problem on the RNP115 / URNP115 nugget ice machine. The manual lists a sensor, valve and drain check.

Model compatibility: U-Line reuses display codes across control platforms, so Er16 may mean something different on another appliance family or generation. Confirm this against your model’s documentation and record your full model number before acting.

Plain language

What this code means

Water drain error: the lower limit water level sensor is not detected within 2 minutes of drain valve operation; it resets after 5 minutes.

What triggers Er16

The RNP115 / URNP115 nugget ice machine opens its drain valve and waits for the lower limit water level sensor to be detected. Two minutes without a detection and Er16 is logged.

At a glance

Code Er16
What it means Water drain error: the lower limit water level sensor is not detected within 2 minutes of drain valve operation; it resets after 5 minutes.
What you can check Check that the drain valve operates and look for a clogged drain. Start the machine again afterward, and the error resets on its own after 5 minutes.
When to call a technician A faulty water level sensor needs replacing by a technician, so book a service visit if Er16 returns after you have checked the drain.

Steps from the manual

  • Replace the water level sensor if it is faulty.
  • Check that the drain valve operates.
  • Look for a clogged drain.
  • Start operation again after the action.

After 5 minutes the machine resets the error automatically.

Compare with these errors

If the trouble is at the water inlet instead, see Er15. For a freezing evaporator, read about Er25; for a warm evaporator while making ice, Er03.

Drain and ice maker service near you

Technicians work the Miami, New York, Houston, Los Angeles and San Diego metro areas. For ice maker repair, ring (844) 706-1091 with the Er16 code, the model number and a note on what you tried with the drain.

Source: U-Line URNP115-IS01A (RNP115) Nugget Ice Machine User Guide & Service Manual, Troubleshooting (u-line.com)

Important safety warning. Do not attempt repairs involving electrical components, gas, water lines, refrigerant or sealed systems. Unplug the appliance if it is safe to reach the outlet, and leave internal diagnostics to a qualified technician.

Code still showing?

Get this U-Line fault diagnosed properly

A returning error code usually needs model-specific testing. Book a visit for a clear estimate — no surprise add-ons.

Code still showing?

Get this U-Line fault diagnosed properly

A returning error code usually needs model-specific testing. Book a visit for a clear estimate — no surprise add-ons.

Book a repair

Tell us what’s wrong — we’ll take it from there

Share a few details and we’ll confirm an appointment. Prefer to talk? Call us and we’ll help right away.

Hours Mon–Sat: 8:00 AM – 7:00 PM
Service area Serving Miami, New York, Houston, Los Angeles and San Diego metro areas.
Response time Response time varies by location and service availability.

Request your repair

Fill in the form below and we’ll confirm an appointment.

Call Book a visit