U-Line Blast Chiller EVAPORATOR LOW TEMPERATURE Code: Non-Critical

Error code EVAPORATOR LOW TEMPERATURE
Appliance Blast Chiller
Quick answer

A non-critical alarm on touch screen U-Line blast chillers when the evaporator runs colder than the setpoint allows.

Model compatibility: U-Line reuses display codes across control platforms, so EVAPORATOR LOW TEMPERATURE may mean something different on another appliance family or generation. Confirm this against your model’s documentation and record your full model number before acting.

Plain language

What this code means

Evaporator temperature too low compared with setpoint (differential parameter LBT); non-critical.

Not every alarm is serious, and this one is not: the manual describes EVAPORATOR LOW TEMPERATURE as non-critical.

At a glance

Code EVAPORATOR LOW TEMPERATURE
What it means Evaporator temperature too low compared with setpoint (differential parameter LBT); non-critical.
What you can check This alarm is not critical, and there is no owner step for it. A large setpoint change inside an automatic recipe can set it off.
When to call a technician If it keeps coming back, ask a technician to adjust the setting. That setting sits behind a password and is not meant for owners.

How it triggers

  • The evaporator reads too low against the current setpoint.
  • Parameter LBT sets the largest gap allowed between setpoint and evaporator temperature.
  • A big setpoint change inside a multistep automatic recipe, with the evaporator staying low for some minutes, can trigger it.

Adjusting LBT

Raising LBT is the manual’s way to avoid the alarm. It is a service menu parameter behind a password, so leave it to a technician.

Where it applies

Touch screen versions of the UCBF559 and UCBF659, and of the UCBF432, UCBF532 and UCBF632. Some pages of the manual print the name as EVPORATOR LOW TEMPERATURE.

Compare

See EVAPORATOR PROBE (S2) and ELECTRICAL FEEDING.

Repair in the Miami, New York, Houston, Los Angeles and San Diego metro areas

For blast chiller repair in the Miami, New York, Houston, Los Angeles and San Diego metro areas, dial (844) 706-1091. The recipe, the model and the alarm wording are useful to have. Our refrigerator repair page gives the overview.

Source: U-Line Blast Chiller User Guide & Service Manual, Pub. 30379 Rev. P 11/2022 (Alarm/Failure List); U-Line Blast Chiller User Guide – Touch Screen Manual (alarm list), Rev 08/04/2015

Important safety warning. Do not attempt repairs involving electrical components, gas, water lines, refrigerant or sealed systems. Unplug the appliance if it is safe to reach the outlet, and leave internal diagnostics to a qualified technician.

Code still showing?

Get this U-Line fault diagnosed properly

A returning error code usually needs model-specific testing. Book a visit for a clear estimate — no surprise add-ons.

Code still showing?

Get this U-Line fault diagnosed properly

A returning error code usually needs model-specific testing. Book a visit for a clear estimate — no surprise add-ons.

Book a repair

Tell us what’s wrong — we’ll take it from there

Share a few details and we’ll confirm an appointment. Prefer to talk? Call us and we’ll help right away.

Hours Mon–Sat: 8:00 AM – 7:00 PM
Service area Serving Miami, New York, Houston, Los Angeles and San Diego metro areas.
Response time Response time varies by location and service availability.

Request your repair

Fill in the form below and we’ll confirm an appointment.

Call Book a visit